 Pressure Gauges
q Monitor pressures in compressed air systems for optimum efficiency q Dual calibrated dials, available for direct or panel mounting q Choice of pressure ranges q Conform to BS 1780 : Part 2, Industrial Class 2 q Range includes Miniature type, 40 mm, pressure gauge suitable for use with Norgren Olympian Series 10 and miniature units
Pressure Gauges R /8 , G 1/8A, 1/4 x 18 N.P.T.
1
Technical Data Medium: Compressed air, oil and gases or liquids which do not corrode copper alloys Operating Temperature: -20C* to +60C *Consult our Technical Service for use below +2C Operating Pressure: 0 - 1,6 bar 0 - 4 bar 0 - 6 bar 0 - 10 bar 0 - 25 bar
Port Connections R1/8, G1/8A, 1/4 x 18 N.P.T.
Alternative Models Stainless steel case with brass movements
Materials Steel, plastic or stainless steel body. Glass or plastic face. Copper/brass or stainless steel movements. Full details available on request.
Ordering Information To order a standard Pressure Gauge, quote model number from table overleaf. For non-standard models please consult our Technical Service.
1/90 8.11.031.01
Pressure Gauges Standard Pressure Gauges
Connection/Type Pressure Range (bar) 0 - 1,6 0-4 0-6 0 - 10 0 - 25 0 - 25 0 - 25 0 - 10 0-6 0 - 10 0-4 0 - 1,6 0 - 25 0 - 10 0-6 0-4 0 - 1,6 0 - 1,6 0-4 0-6 0 - 10 0 - 25 Port Connection R1/8 R1/8 R1/8 R1/8 R1/8 1 /4 x 18 N.P.T. R1/8 1 /4 x 18 N.P.T. 1 /4 x 18 N.P.T. R1/8 R1/8 R1/8 G1/8A G1/8A G1/8A G1/8A G1/8A R1/8 R1/8 R1/8 R1/8 R1/8 Nominal Diameter 50 50 50 50 50 40 40 40 40 40 40 40 62 62 62 62 62 50 50 50 50 50 Model 18-013-010 18-013-011 18-013-012 18-013-013 18-013-014 18-013-905* 18-013-908 18-013-909* 18-013-913* 18-013-989 18-013-990 18-013-991 18-013-992 18-013-993 18-013-994 18-013-995 18-013-996 18-013-024 18-013-025 18-013-026 18-013-027 18-013-028 Weight kg 0,83 0,83 0,83 0,83 0,83 0,93 0,67 0,80 0,21 0,05 0,05 0,04 0,14 0,13 0,14 0,13 0,14 0,67 0,63 0,86 0,87 0,90
Centre back
Centre back (miniature)
Centre back (panel mounted)
Bottom
Actual case diameter may exceed nominal diameter by 5 mm. *Stainless steel cases with stainless steel movements for 22 Series range. All stainless steel gauges are not strictly to NACE standard MR-01-75.
Non-standard Models
For Pressure Gauges with stainless steel cases and brass movements or other options, please consult our Technical Service.
Centre Back Mounted Pressure Gauges
18-013-010 18-013-011 18-013-012 18-013-013 18-013-014 R1/8 R1/8 R1/8 R1/8 R1/8
14.2 + 0.2 50 8 max 14 4
33 7.0
8.11.031.02
Pressure Gauges Miniature Centre Back Mounted Pressure Gauges
18-013-905 18-013-908 18-013-909 18-013-913 18-013-989 18-013-990 18-013-991
42.3 40 14 max 12.7 24
1
/4 x 18 N.P.T. R1/8 1 /4 x 18 N.P.T. 1 /4 x 18 N.P.T. R1/8 R1/8 R1/8
Centre Back Panel Mounted Pressure Gauges
18-013-992 18-013-993 18-013-994 18-013-995 18-013-996
6
9.5 max
G1/8 A G1/8 A G1/8 A G1/8 A G1/8 A
62
52
50
23 57 max
1/90
8.11.031.03
Pressure Gauges Bottom Mounted Pressure Gauges
18-013-024 18-013-025 18-013-026 18-013-027 18-013-028 R1/8 R1/8 R1/8 R1/8 R1/8
50
28
R 1/8
12.7
32.5
9.5 14
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under `Technical Data'. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN MARTONAIR. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
8.11.031.04


▲Up To Search▲   

 
Price & Availability of 18-013-993

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X